Reefer container pre-purchase inspection field guide, Van Blanc Brantford, Issue 218

Quick Answer: A reefer container pre-purchase inspection Ontario needs three passes: refrigeration unit (Carrier, Thermo King, Daikin, Star Cool) running a full PTI cycle, insulated shell at R-value 6 to 7 per inch of polyurethane core, and T-bar floor with clear condensate drains. Run the PTI before money moves. Real Brantford yards, real reviews (4.9 / 124+), real 1-3 day delivery. Family-operated since 1995.

Reading time: about 14 minutes.

Why Do Reefer Inspections Differ From Dry Box Checks?

A reefer inspection differs from a dry box check because a refrigerated container fails on small hidden faults, not obvious ones. A dry box shows rust holes at a glance. A reefer can look fine in the yard while a worn compressor or blocked drain only shows under load, which is why a full PTI cycle is the deciding test.

A standard 20ft or 40ft dry container fails on big visible things: a rust hole the size of a fist, a sprung door, a floor board that punches through. A reefer (refrigerated shipping container) fails on small invisible things. A capillary tube that whistles a fraction off pitch. A condensate drain stuffed with dried mango pulp from a 2019 banana run out of Costa Rica. A microprocessor that boots clean but won’t hold set point under load. None of that shows in a parking-lot walkaround.

If you are still weighing the basics of how a refrigerated container is built and what it can hold, start there, then come back for the inspection detail. Most Ontario buyers searching for a used reefer are coming from one of four lanes. Cannabis growers who need cold storage for cured flower at 4 to 8 degrees Celsius. Craft breweries staging kegs at 2 to 4 degrees. Greenhouse and produce operators wanting a chilled holding room for hardier crops. Pharmacy and lab buyers wanting a temperature-controlled inventory cell. Each of those buyers needs the unit to actually work for ten years, not look like it works on the day of sale.

Paul LeBlanc, owner: “A dry box you can read from the gate. A reefer hides its problems inside the refrigeration unit and behind the panels, and the only honest way to find them is to run the machine. I have been buying and selling containers for nineteen years, and the reefers that come back to bite a buyer are always the ones nobody powered up before the cheque cleared.”

That’s why the longer checklist we work through on every yard pickup takes longer on a reefer than on any dry box. We don’t sell a unit that hasn’t completed a full Pre-Trip Inspection (PTI) cycle in our yard with a clipboard recording each test result. Below is the same routine, written so an Ontario buyer can run it before paying anyone.

The four-component anatomy of a reefer

A reefer is not a single thing. It is four systems stacked into one steel box: the refrigeration unit (compressor, condenser, evaporator, controller) bolted into the front wall, the insulated shell (sandwich-panel walls and roof with polyurethane or vacuum-insulated panel core), the cargo space (T-bar aluminum floor, evaporator fans, return air bulkhead), and the power and control system (3-phase 460V power cord, controller display, USB or serial data port). Each layer has its own failure modes. Each layer needs its own inspection pass.

What Is the Three-Pass Method for Inspecting a Reefer?

The three-pass method is a reefer inspection split into three deliberate sweeps: a unit-off cold inspection, a controller-on dry run, and a full PTI under load. Christian walks every reefer with the buyer when they visit the yard. He runs the inspection in three deliberate passes rather than one wandering tour. Each pass has a job. Skip a pass and you miss a category of fault.

Pass one is the unit-off cold inspection. Steel exterior, hinge gear, door seals, panel skins, T-bar floor, condensate drains, evaporator coil visible through the return-air grille. The compressor sits silent, the lights stay off, you read the unit as a static object. This is where dents, repair welds on the front wall around the unit, and panel delamination show up. Closed eyes work better than open ones for some of this: run a palm along the inside wall and feel for cold spots where insulation has settled.

Pass two is the controller-on dry run. Plug in to 3-phase shore power. The display boots. The controller cycles through self-test. Sensors light up: supply air, return air, defrost, ambient, evaporator coil, condenser coil. Compressor stays off for the first three to four minutes while pressures balance. Then it engages and you listen.

Pass three is the full PTI. The unit runs a programmed cycle for anywhere from 20 minutes (Auto Short PTI 1) to 4.5 hours (Full PTI) depending on what the controller supports. Temperature pull-down is timed. Defrost cycle is forced. Heat strip is exercised. Alarms are checked and cleared. At the end you have a printout (or a controller-stored log) that says PASS or NO PASS by section.

If a seller refuses pass three, walk. The PTI is the only test that proves the unit holds set point under load, and that test costs nothing but time. A seller who won’t run it is a seller who already knows the result.

How Do You Inspect a Reefer Refrigeration Unit?

The four refrigeration unit manufacturers you will see on used Ontario stock are Carrier (Transicold, ThinLINE, NaturaLINE generations), Thermo King (Magnum, MP-4000, SLXi generations), Daikin (LXE10, ZESTIA), and Star Cool (Standard, Integrated). Mitsubishi MCI shows up occasionally on Pacific-routed boxes. Each manufacturer has its own quirks but the inspection language is shared.

What Christian listens for during the first compressor cycle

  • Startup whine pitch. A clean compressor startup is a low, steady rising hum. A whine that climbs and stays high points at a worn bearing or a refrigerant charge problem.
  • Condenser fan engagement. Should kick on within 60 seconds of compressor start once head pressure rises. A condenser fan that never engages on a hot day means the head will trip on high pressure within an hour.
  • Evaporator fan smoothness. Variable-speed evaporator fans on newer generations should ramp without a vibration shake. A rattling evap fan points at a bent blade or a worn bushing.
  • Capillary or expansion valve hiss. Some hiss is normal. A whistle or a frosty patch downstream of the valve means a partial blockage or refrigerant flash.
  • Refrigerant sight glass (where present). Clear flowing liquid is right. Bubbles or foaming mean the charge is low and the unit needs a leak test before sale.

The compressor is the single most expensive component to replace. On a 40HC Carrier ThinLINE, a rebuilt scroll compressor with reefer-grade refrigerant recharge is one of the largest single line items in reefer service, and on a Thermo King Magnum the cost climbs higher still because of the larger displacement and parts availability. That means a reefer with a failing compressor can cost far more to put right than the gap between it and a working one, and you are sometimes better off paying up front for a unit that has just passed a fresh PTI.

Christian LeBlanc, second-generation operator: “The thing buyers miss is that a reefer that fires up in the yard does not mean a reefer that holds 2 degrees Celsius for three days straight under a Brantford August sun. I have seen units boot, run for ten minutes, satisfy the buyer, and then trip a high-pressure alarm twelve hours later when the condenser cycles fail in real heat. That is why we run the full PTI before you pay. Anyone can flick a switch. Holding set point under load is the actual question.”

What Is a PTI and Which One Should You Ask For?

PTI stands for Pre-Trip Inspection. Every refrigerated container leaving a reputable yard runs one before delivery. The standard breaks down into three depths.

PTI TypeDurationWhat It TestsUse Case
Auto Short PTI 1~20 minutesController boot, sensor readings, compressor start, fan operation, defrost heater pulse, alarm clearQuick yard verification, between loads
Auto Long PTI 2~3 hoursAll of PTI 1 plus pull-down test, set-point hold at chill (+2 C), freeze (-18 C), and ambient recoveryPre-loading for sensitive cargo
Full PTI2.5 to 4.5 hoursAll of PTI 2 plus high-pressure switch test, refrigerator response at 0 C, +25 C, and -17.8 C, capacity verification under simulated loadPre-purchase verification, post-major-repair

For a pre-purchase decision on a used Ontario reefer, ask for the Full PTI. The Auto Long covers most operational reality but the Full PTI is the only one that exercises the high-pressure switch and forces the refrigerator through the full temperature band a buyer will actually demand of it. Most Ontario suppliers can run a Full PTI overnight while you sleep, so the time cost is yours to walk away from the yard and come back next morning.

What a passing PTI looks like on paper: each subsystem returns a value within tolerance, the defrost cycle initiates and terminates on schedule, no alarms are logged during the run, and the set-point hold variance is within 0.5 degrees Celsius across a one-hour steady-state segment. A failing PTI shows an alarm code at the failure point and aborts the rest of the test sequence automatically.

The PTI receipt trick

Ask for the printed or controller-stored PTI log dated within seven days of purchase. If the seller offers you a PTI log dated four months ago, that log is meaningless. Refrigerant pressures, sensor drift, and bearing wear can shift in ten weeks. A current PTI is the actual purchase decision document. We keep a paper copy on the dashboard of every reefer delivery truck so the buyer sees the printout the moment the unit arrives.

How Good Is Reefer Insulation and What R-Value Does It Give?

The shell is what makes a reefer a reefer. A failed compressor can be replaced. A failed insulation core cannot, not economically. The shell is the bet you make for the next 15 years.

Standard reefer shells use a sandwich panel construction: two thin metal skins (often stainless steel inner, painted steel outer, sometimes a fiberglass inner on older builds) with a foamed-in-place polyurethane core. Core thickness runs 60 to 100 millimetres. Polyurethane gives an R-value of roughly 6 to 7 per inch of thickness, so a 75 mm wall (about 3 inches) lands near R-18 to R-21 across the wall section. Roof panels are typically thicker and reach R-25 or higher. Door areas are the weak point because the seal interrupts the continuous foam.

Newer premium units use Vacuum Insulated Panels (VIPs) layered with polyurethane. A VIP can deliver R-30 per inch or higher, which lets the wall hold a thinner section while still beating standard foam thermal performance. You will see VIP construction on recent Maersk Star Cool and high-end Carrier units. For pre-purchase inspection it does not change the test, but it tells you the unit is a younger build with better thermal economy in operation.

How to find delaminated insulation without cutting the wall open

Run a hand along the interior wall after the unit has been running on chill for an hour. The wall should be uniformly cool. A warm spot is a void where insulation has settled or delaminated from the skin. On a hot day you can sometimes see condensation pattern differences from the outside: a panel section that sweats more than its neighbours is a section losing more heat. Bring a non-contact infrared thermometer and check for surface temperature variance greater than 4 degrees Celsius across adjacent panels. That variance is your evidence.

Old refrigerant in a reefer is its own concern. Pre-1995 units sometimes still operate on R-22, which is being phased down under the Montreal Protocol amendments. R-134a units are still serviceable but require licensed refrigerant handling. Newer NaturaLINE Carrier units use R-744 (CO2) as a natural refrigerant. Confirm what your unit runs on before you commit. An R-22 unit with a slow leak is an expensive ongoing maintenance commitment because the refrigerant itself keeps getting harder to source.

How Do You Check the T-Bar Floor and Condensate Drains?

The cargo space inside a reefer has a different floor system than a dry box. Instead of plywood, you get extruded aluminum T-bar profiles that run lengthwise. The shape of the T raises cargo off the floor and creates channels that let chilled air pass underneath the load. Without that floor design, the cargo at the bottom of a pallet stack would warm up before the cargo at the top.

T-bar floor inspection points

  • Bent or crushed sections. Forklift damage shows here first. A flattened T-bar reduces airflow and creates hot pockets above it. Replacement aluminum extrusion is available, but the installation labour rises with each linear foot of profile that has to be swapped, so a floor with widespread crush damage is a real negotiating point.
  • Corrosion at the rear-door drain channels. Salt water from coastal routes, citric acid from rotten produce, and bleach from misguided cleaning all eat T-bar over time. Look for white powder on the aluminum surface.
  • Loose or missing T-bar fasteners. The profiles should be tight to the cross-beam structure. A T-bar that lifts when you stand on it is structurally compromised.
  • Drain channel function. Pour a litre of water at the back of the cargo space. It should drain forward and exit through the drain at the front of the floor near the evaporator. Standing water after 60 seconds means the drains are blocked.

Condensate drains are the smallest part of the reefer and one of the most overlooked. The evaporator coil produces condensation as it cools warm air. That water has to leave the box. Most reefers have two to four small drain ports near the front interior corners that route water through the front wall and out the underside. If those drains are blocked with dried product residue (fish bones, sticky fruit pulp, biofilm from a meat run) the water backs up and either freezes the evaporator over or rots the floor channel.

Run a thin wire down each drain. It should come out the bottom side of the unit cleanly. If you hit resistance, the drain is blocked and the unit needs a flush before purchase. This is a 30-minute job at the yard but it is a job that someone has to do.

The smell test. Walk in. Close the door behind you. Breathe. A clean reefer smells like cold metal and a faint mineral note from the aluminum. A reefer with biofilm smells faintly sweet, fishy, or sharply chemical depending on its last cargo. That smell does not always wash out. Ask Christian about the unit that came in after a fish run from 2018 that took three rounds of food-safe sanitizer over a month before it was clean enough to resell.

Can You Run a Reefer on Residential Power?

You cannot run a standard container reefer on ordinary residential power, and that is the single most common surprise for Ontario buyers. Container reefers run on 3-phase 460V power as standard. That is industrial power. Your residential 200-amp service does not have 3-phase available without a utility upgrade plus a transformer.

Three power options for a 3-phase reefer on a non-3-phase site

One: install a phase converter (a rotary phase converter costs more than a static converter but is far more reliable on the motor loads a compressor presents). Two: install a dedicated 3-phase service drop with the local utility (Hydro One or your municipal utility), where the cost is driven mostly by how far your site sits from the nearest 3-phase line. Three: convert the unit to a single-phase variant using a service that swaps the motor and controller, where the price depends on the unit generation and parts. We have done all three for buyers and we tell you up front which makes sense for your site.

The power cord itself is replaceable but worth a look. The 460V cord with the 3-phase plug on the end is 25 to 50 feet long depending on build. The plug should be a 32-amp 5-pin twist-lock IEC pin-and-sleeve type in most cases. Inspect for: nicks in the jacket exposing wire, loose strain relief at the cord entry into the unit, pin discoloration or arc burn at the plug face.

The other power consideration is whether the unit supports gen-set operation. Some reefers ship with a hookup for a clip-on diesel generator (gen-set) used during over-the-road transport when shore power is not available. If you are buying for static yard installation you do not need that hookup, but if your site has rolling power outages a gen-set ready unit gives you fallback capacity.

Does the Controller Generation Matter When Buying a Reefer?

The controller is the brain. It is also the part that ages out fastest in software terms. A Carrier Transicold from 2002 still runs but its software predates modern data logging requirements. A 2018 Thermo King MP-4000 logs every minute of every cycle and exports through USB. The difference matters if your cargo needs traceability (pharma, certified organic, premium produce buyers asking for chain-of-custody temp logs).

Controller GenerationLoggingConnectivitySoftware Support
Pre-2005 (Micro-Link 1, early Thermo King MP-3000)Manual, paper temp chartsNone standardManufacturer support discontinued
2005-2012 (Micro-Link 2, Carrier Advance, TK MP-3000 series)Internal memory, USB exportUSB, occasional CANLimited; parts still available
2013-2019 (Micro-Link 3, NaturaLINE, MP-4000)Full event logging, USB, telematics-readyUSB, CAN, optional cellularActive
2020+ (Carrier Lynx, Thermo King TracKing, Maersk Remote Container Management)Continuous cloud telemetryCellular, Bluetooth, APIActive

Set-point range varies by generation and manufacturer. Modern reefers hold from -30 degrees Celsius (deep frozen for ice cream, seafood, certain pharma) to +30 degrees Celsius (chilled but warm holding for produce in winter). The chill band that most Ontario buyers care about (+2 to +8) sits comfortably inside every generation. The deep frozen band is where older units sometimes lose capacity over time as compressor efficiency declines.

Ask the seller to demonstrate a set point change during the inspection. Punch in -18, watch the unit ramp toward freezing, then punch in +4 and watch it cycle back up. The transition behaviour tells you more than any static reading. A unit that lags 20 minutes behind its set point change has a refrigerant or sensor problem the seller may not have flagged.

Should You Buy a Non-Operating Reefer for Insulated Storage?

A meaningful slice of Ontario reefer buyers do not need refrigeration. They need the insulated shell. A non-operating reefer (sometimes called an ex-reefer, NOR unit, or insulated dry container) has the refrigeration unit removed or disabled, but the polyurethane sandwich-panel walls, T-bar floor, and condensate drainage are intact. That gives you an R-18 to R-21 insulated box at roughly half the price of a working reefer.

What Ontario buyers use insulated NOR units for: wine cellar overflow at small vineyards, root cellar replacements for farms, sound-reducing workshops, climate-buffered electronics storage, beekeeping winter shelters, and quiet writing studios. We cover those builds in more detail in our guide to putting an ex-reefer shell to work. The insulation that was designed to hold +2 degrees Celsius against +30 ambient also holds +18 indoors against -15 outdoors with surprisingly little supplemental heat.

Local Ontario use case: vineyard insulated NOR

Niagara and Prince Edward County wineries use ex-reefers as overflow cellars during fall crush. The unit holds a stable 12 to 14 degrees Celsius with passive ventilation alone through most of the year, and a small mini-split or window unit covers the deepest summer weeks. Compared to building an insulated outbuilding from scratch or expanding the main cellar, both of which carry long construction timelines, a 40HC NOR delivered to the vineyard is the practical answer for capacity expansion of two to four years before the permanent build.

Pre-purchase inspection on a NOR is shorter than on a working reefer because the refrigeration unit comes out of the equation. You inspect shell, panel integrity, T-bar floor, drains, doors and seals, and panel skin condition. Most NOR buyers ask us to leave the wiring harness in place so the option to retrofit refrigeration later is preserved, even if they never exercise it.

Ready to price your container?

Tell us the size and your postal code and we’ll send back an honest, all-in number, container, delivery, and placement, usually within 1-3 days. No pressure, no mystery fees.

Family-run in Brantford since 1995 · 200+ containers in stock · 4.9★ across 124+ Google reviews · every box graded by a person, walk it before it lands.

We’d rather quote you the right box than sell you the big one. If a 20ft does the job, we’ll tell you, and we’ll tell you why.

What Drives the Price of a Reefer Container in Ontario?

Ontario reefer pricing in 2026 sorts into four bands by type and grade, from a non-operating shell at the bottom up to a factory-current reefer with a manufacturer warranty at the top. Rather than quote a moving number, the more durable thing to understand is what drives a reefer quote up or down, because those drivers hold regardless of the week’s steel pricing, shipping-line return cycles, and seasonal demand from cannabis and produce buyers.

Type and GradeWorking / Non-WorkingWhat Drives the QuoteBuyer Profile
20ft used reefer, post-PTIWorkingCompressor hours and PTI recency set the band; older units price lower but carry more service riskBrewery cold storage, small cannabis op, restaurant overflow
40ft used reefer, post-PTIWorkingLarger displacement and controller generation lift it above the 20ft; cargo-worthy grade and a fresh PTI hold valueMedium cannabis grow, produce wholesaler, food processor
20ft or 40ft one-trip new reeferWorkingTop band: near-new shell, current telematics controller, and full factory warranty push it well above used stockPharmacy/lab, certified-cold-chain, premium produce
20ft or 40ft non-operating (NOR/ex-reefer)Insulated shell onlyLowest band because the refrigeration unit is gone; shell condition, panel integrity, and door seals decide itWinery overflow, root cellar, workshop, quiet studio

The grading language matters. The same yard walk-through that grades a dry box uses the same four-tier IICL system here: One-Trip (essentially new, one ocean crossing only), Cargo Worthy (CW, recertified for international shipping), Wind and Watertight (WWT, sealed but not export-certified), and As-Is (older units sold for parts or insulated-shell-only conversion). For reefers, the PTI pass adds a fifth dimension that overlays the cosmetic grade: a CW-grade reefer with a recent passing PTI is the practical Ontario buy-it-and-use-it grade for most working applications.

Christian LeBlanc, second-generation operator: “Paul and I have watched the reefer market through the cannabis boom, the supply chain crunch, and the post-pandemic normalisation. The pattern that stays constant is that the bin which is cheaper on Facebook is the bin where the PTI was never run, the compressor is end-of-life, and the buyer is calling us six weeks in asking if we can rescue them. We can sometimes. It is always more expensive than buying right the first time.”

Many people call us saying they found a reefer far below the market on Facebook. Two weeks later they call back saying they got scammed. Don’t fall for it: the bin that is suspiciously cheaper on Facebook is the bin where the PTI was never run. The defective compressor that follows that purchase often costs more to replace than the gap that made the listing look like a deal, which means the apparent discount becomes a loss before you have moved a single pallet of product into the unit. That math does not change.

If you are weighing the buy decision on a refrigerated container today, the safer route is walking a unit through the full check before you wire any money on a box you have seen in person. Drive to Brantford. Watch the PTI run. Read the printout. Pay only after the box has proven it can do its job for the next 15 years.

Frequently Asked Questions

What is a PTI on a reefer container?

PTI stands for Pre-Trip Inspection. It is a controller-driven test cycle that exercises the compressor, sensors, fans, defrost heater, and pressure switches on a refrigerated container before it carries cargo. A Full PTI takes 2.5 to 4.5 hours and is the standard pre-purchase test for any used reefer in Ontario.

How much does a used reefer container cost in Ontario in 2026?

A working 40ft used reefer costs more than a 20ft because of its larger displacement, and both sit well above a non-operating insulated shell (ex-reefer), which has had its refrigeration unit removed. One-trip new reefers are the top band. Where any unit lands depends on age, compressor hours, controller generation, and how recent its passing PTI is, so the most reliable way to compare is by those drivers rather than a fixed figure.

Which manufacturers make reefer container refrigeration units?

The four common manufacturers are Carrier (Transicold, ThinLINE, NaturaLINE), Thermo King (Magnum, MP-4000, SLXi), Daikin (LXE10, ZESTIA), and Star Cool (Maersk Container Industry). Mitsubishi MCI appears occasionally on Pacific-routed boxes. Each has its own software ecosystem but the inspection routine and PTI structure is shared across all four.

Can I run a reefer container on regular residential 240V power?

No. Standard reefer units require 3-phase 460V industrial power. Options include a rotary phase converter, a utility 3-phase service drop, or a single-phase motor and controller conversion, each with its own cost depending on your site distance from 3-phase lines and the unit generation. Discuss the site power situation before buying so the unit matches what your service can deliver.

What is a non-operating reefer (NOR) and why would I want one?

A non-operating reefer is a refrigerated container with the refrigeration unit removed or disabled, sold for its insulated shell alone. It gives you an R-18 to R-21 insulated box for roughly half the working-reefer price. Ontario buyers use NOR units for winery overflow cellars, root cellars, quiet workshops, and climate-buffered storage.

How long does a reefer container last?

The insulated shell lasts 20 to 30 years with normal use. The refrigeration unit lasts 10 to 15 years on average before major compressor service is needed. Total useful working life on a well-maintained reefer is 15 to 25 years. The shell typically outlasts the refrigeration unit by 10 years, which is why ex-reefer NOR conversions are a healthy second life for these boxes.

What temperature range can a reefer container hold?

Modern reefers hold -30 degrees Celsius (deep frozen) to +30 degrees Celsius (warm chill). The chill band most Ontario buyers care about (+2 to +8 degrees Celsius, the standard food-safe cold-chain range) sits comfortably within every generation of unit. Deep-frozen capacity weakens slightly on older units as compressor efficiency declines.

How do I check if reefer insulation is still good?

Run the unit on chill for an hour. Run a hand or non-contact infrared thermometer along the interior wall. Uniform cool surface temperature is correct. Warm patches greater than 4 degrees Celsius variance between adjacent panels indicate insulation voids, panel delamination, or moisture intrusion. Exterior condensation pattern differences on a hot day show the same problem from outside.

Why does my reefer condensate drain matter?

The evaporator coil produces water as it cools warm air. That water exits through small drain ports near the front of the cargo space. Blocked drains back water up, freeze the evaporator over, or rot the T-bar floor. Test by pouring a litre of water in the cargo space and watching it exit through the drains within 60 seconds. Slow drainage means a flush is needed.

Can I see a reefer in person before buying in Ontario?

Yes. Van Blanc has four Brantford yards stocked with working reefers, non-operating units, and one-trip new builds. Christian or Paul walks every reefer with the buyer, runs a live PTI cycle while you watch, and prints the result before any money moves. Worth the drive for unbeatable quality, family customer service with 30 years of experience.

Sources

  1. International Organization for Standardization. (2018). ISO 1496-2:2018, Series 1 freight containers, Specification and testing, Part 2: Thermal containers. iso.org
  2. International Maritime Organization. (1972, amended). International Convention for Safe Containers (CSC). imo.org
  3. GCS-Reefer. (2025). PTI: Reefer container performance test (Auto Short, Auto Long, Full PTI specifications). gcs-reefer.com
  4. Aztec Container. (2024). Are Refrigerated Shipping Containers Insulated? Polyurethane R-value and sandwich-panel construction. azteccontainer.com
  5. Transport Canada. (2025). Cargo Securement Standard 10, Containerized Cargo. tc.canada.ca

Reach Van Blanc in Brantford

We have been supplying shipping containers across Ontario since 1995. Our yard is at 90 Morton Avenue East in Brantford, and we deliver right across the province with fast 1-3 day delivery and every quote carries a real lead time, not a hopeful one. If you are buying a reefer, drive in and watch the PTI run before you pay. That is the test that matters.